Dedicated Micros ©2006
118
DS2 Network Guide
Dial / Retry Timeout If for any reason the initial connection attempt between the unit
and the remote station fails then the unit will wait for the specied
time period before attempting to re-connect. This allows the time
period to be dened in minutes and seconds.
Alarm Telnet Server Port This identies the port number that will be used for remote
monitoring station allowing them to ‘listen’ for alarm messages
from the unit.
The default setting is 0023, however if this port is already being
used on the network it is possible to dene a different port
number.
REPORT SETTINGS
This submenu determines when the unit will create a report.
Alarm reporting
Camfail reporting
Startup reporting
Tamper reporting
Disabled
Disabled
Disabled
Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Enabled, Disabled
Report
Function Description
Alarm Reporting This must be enabled for the unit to automatically connect and
report on alarm, it must also be enabled in the Alarm Zone menu.
Camfail Reporting Enabling this option will force the unit to automatically connect
and report when it has identied camera failure on any of the
enabled video inputs.
Startup Reporting When enabled the unit will be forced to transmit an alarm report
to the central monitoring station when the unit starts up, this will
identify any system resets.
Tamper Reporting The unit supports End Of Line for the onboard alarm inputs, if
these have been enabled it is possible to identify that the alarms
have been tampered with, when this occurs enabling this option
will force the DS2 to send a message to a remote station to
identify alarm tamper.
E-mail Settings
If the unit has been congured to transmit e-mails on alarm, camera fail, etc it is necessary to
congure the e-mail settings.